The Prevena Plus 125 system is a single-use, disposable unit designed for managing surgical incisions. It employs negative pressure therapy to promote healing. This system includes the therapy unit, patch strips, a canister, and a specialized dressing.

Overview of the Prevena Plus 125 System

The Prevena Plus 125 system is an advanced incision management solution that utilizes negative pressure wound therapy. This portable, disposable system is designed to manage closed surgical incisions and some open wounds. It works by applying controlled negative pressure of -125mmHg to the wound site, which helps remove fluids and protect the incision. The system includes a therapy unit, patch strips for sealing, a fluid collection canister, and a specialized dressing. It is available in both 7-day and 14-day configurations, providing continuous therapy for the specified duration. The system’s primary function is to reduce the risk of infections and seromas by creating an optimal healing environment. It simplifies postoperative care and aims to improve patient outcomes.

Components of the Prevena Plus 125 System

The Prevena Plus 125 system includes several key components⁚ the Prevena 125 Therapy Unit, Prevena Patch Strips, a 45 mL Canister, and a specialized Prevena Dressing.

Prevena 125 Therapy Unit

The Prevena 125 Therapy Unit is a crucial part of the incision management system. It’s a portable, battery-powered device that delivers controlled negative pressure to the surgical site. This unit works by creating a vacuum-like environment, which aids in fluid removal and promotes healing. The therapy unit is designed for single-use and is disposable. It plays a central role in the system’s ability to manage closed surgical incisions, and the device is compatible with all 3M Prevena dressings. The unit is designed to be used in conjunction with other components of the system, to improve patient outcomes. The unit is designed to be simple to use.

Prevena Patch Strips

Prevena Patch Strips are a key component of the Prevena Plus 125 system, designed to enhance the seal around the dressing. These strips are used to help prevent leaks and maintain the integrity of the negative pressure environment. They are applied strategically around the edges of the Prevena dressing to ensure a secure and airtight seal. This helps to optimize the effectiveness of the negative pressure therapy. The patch strips are disposable, single-use items. Proper application of these strips is important for the overall success of the incision management system, and they help prevent complications. The strips work in tandem with the dressing.

Prevena 45 mL Canister

The Prevena 45 mL Canister is a sterile, single-use reservoir designed to collect wound fluids during negative pressure therapy. This canister is an essential part of the Prevena Plus 125 system, securely attaching to the therapy unit. It serves as a collection point for exudate and other fluids removed from the surgical site via the negative pressure. This fluid collection is vital for managing the surgical environment. The canister is carefully designed to maintain a closed system, preventing contamination and ensuring patient safety. The 45 mL capacity is adequate for typical use cases, and the canister is easily disposable after use. The Prevena 45 mL Canister contributes to the overall effectiveness of the system.

Prevena Dressing

The Prevena Dressing is a key component of the Prevena Plus 125 system, designed to be applied directly over the closed surgical incision. This specialized dressing works in conjunction with the therapy unit to maintain a closed environment and facilitate the removal of fluid. The dressing is typically made of a material that is both comfortable for the patient and effective in sealing the incision site. It helps create an airtight seal, which is essential for the negative pressure therapy to function correctly. The Prevena dressing is designed to be flexible and conform to the contours of the body. The dressing also plays a vital role in protecting the incision from external contaminants, reducing the risk of infection, and facilitating healing.

Functionality and Operation

The Prevena Plus 125 system applies continuous negative pressure of -125mmHg to the surgical site. This action helps remove fluids and manage the incision environment effectively, promoting healing.

Negative Pressure Therapy at -125mmHg

The Prevena Plus 125 system utilizes a consistent negative pressure of -125mmHg to manage closed surgical incisions. This controlled vacuum-like force helps draw fluid away from the surgical site, which aids in reducing the risk of complications. The application of this specific pressure is crucial for maintaining an optimal healing environment, promoting tissue apposition, and minimizing the formation of seromas. The continuous negative pressure also facilitates the removal of exudate, helping to keep the surgical area clean and dry. This mechanism is integral to the system’s effectiveness in preventing infection and supporting the body’s natural healing processes. The system’s design ensures that this pressure is consistently delivered throughout the therapy duration.

Duration of Therapy (7-Day and 14-Day Units)

The Prevena Plus 125 system offers two main therapy durations⁚ 7-day and 14-day units, catering to different patient needs and surgical procedures. The 7-day unit is designed for shorter-term incision management, while the 14-day unit provides extended therapy for more complex cases or when longer support is required. Both units deliver consistent negative pressure of -125mmHg throughout their respective durations, ensuring uninterrupted treatment. The choice between the two depends on the specific circumstances of the patient’s incision and the healthcare provider’s assessment. The single-use nature of these units means that they are intended for a complete therapy cycle, eliminating the need for battery changes or maintenance. These options provide flexibility in managing post-operative recovery effectively.

Intended Use and Benefits

The Prevena Plus 125 system is intended for closed surgical incisions. It aids in fluid removal, reducing the risk of infections and seromas. This promotes better healing outcomes.

Management of Closed Surgical Incisions

The Prevena Plus 125 system is specifically designed to manage the environment of closed surgical incisions. By applying continuous negative pressure of -125mmHg, the system helps to draw fluid away from the surgical site. This mechanism is crucial for reducing the risk of complications, such as infections and seromas, which can hinder the healing process. The system’s components, including the dressing, therapy unit, and canister, work together to create a protected and controlled environment for the incision. This promotes optimal conditions for tissue recovery and minimizes the potential for adverse events post-surgery, ultimately contributing to improved patient outcomes. The system can be used on both linear and non-linear incisions.

Fluid Removal from Surgical Sites

The Prevena Plus 125 system actively facilitates fluid removal from surgical sites through the application of consistent negative pressure. This controlled suction at -125mmHg draws exudate away from the incision area and into the 45mL canister. This removal of fluid is essential, as accumulated fluid can impede proper healing and increase the risk of infection and seroma formation. By effectively managing the fluids at the surgical site, the Prevena Plus 125 system helps to create an environment that supports optimal tissue regeneration and reduces the potential for post-operative complications. The system provides a sterile and contained method for fluid management, which is very important in surgical recovery. The collection of fluids is clearly visible in the canister.

Reduction of Infections and Seromas

The Prevena Plus 125 system is instrumental in minimizing the risk of infections and seromas at surgical sites. By continuously applying negative pressure, the system removes fluids and exudate, which are potential breeding grounds for bacteria. This reduction in fluid accumulation helps create a drier and more stable environment, which is less susceptible to infection. Furthermore, the consistent negative pressure also assists in preventing the formation of seromas, which are collections of fluid that can occur under the skin. The use of the Prevena system promotes a more effective and efficient healing process by proactively addressing these common postoperative complications, ultimately leading to better patient outcomes. This proactive approach can significantly contribute to a smoother recovery period.

Instructions and Safety

It is crucial to adhere to healthcare provider’s guidance when using the Prevena Plus 125. Familiarize yourself with all symbols. Do not use if packaging is damaged and consult the instructions.

Following Healthcare Provider Instructions

The proper use of the Prevena Plus 125 system is paramount for effective wound management, and therefore, strict adherence to your healthcare provider’s instructions is absolutely essential. Your healthcare provider will determine the appropriate duration of therapy, which could be either 7 or 14 days, based on your specific needs. Furthermore, they will guide you on whether dressing changes are required and, if so, how often these changes should occur. It’s critical to understand that this system is designed to work under specific parameters, and deviating from your provider’s recommendations could negatively impact the outcome. They will provide specific guidance for your unique situation.

Explanation of Symbols Used

The Prevena Plus 125 system utilizes specific symbols on its packaging and device to convey important safety and usage information. One crucial symbol indicates that the device is for prescription use only, highlighting the necessity of a physician’s order for its application. Another symbol, IP22, denotes the device’s Ingress Protection rating, signifying its level of protection against solids and liquids. Additionally, a symbol signifies the device is a Type BF applied part, relating to its electrical safety classification. The user must be aware of the meaning of all symbols. Always consult the provided instructions for use for a comprehensive explanation of all symbols, ensuring correct and safe operation.